Revolution SLCX

More Views

Revolution SLCX ATEX Long Cased Axial Flow Fan
Elta Select Product

Quick Facts

  • 7 standard sizes from 355mm to 710mm.
  • Air volume flow rates up to 6.8 m³/s.
  • Static pressure up to 800 Pa.
  • Suitable for operating temperatures up to +40°C.
  • Suitable for extract or supply systems.
  • Available in AC.

Delivery

  • Available for next day delivery with Elta Select
Applications
Features & Benefits

Design appeal

Classified for constructional safety and the requirements stated in 94/4/EU (ATEX) directive, Gas Zone and ignition temperature protection to Ex II 2G c IIC T4 X.

Material strength

Fan casings are heavy guage, sheet steel, roll formed and welded and hot dipped galvanised after fabrication to BS 729.

Warranty

Each SLCX has a 12 month warranty.

Performance

Adjustable pitch aerofoil section impellers with blades made from high quality carbon filled anti – static material for enhanced performance. Hubs are die cast aluminium.

Mounting

Fans can be mounted in any position.

Full accessory range

Speed controllers, Motor protection.

Quality assurance

All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.
Specification

Casing

The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dip galvanised to BS EN ISO 1461:1999 after fabrication.

Motors

Motors according to Gas Zone, Ignition Temperature and Protection to Ex II 2G c IIC T4 X.

Impellers

Adjustable pitch aerofoil impellers are provided with blades made from high quality carbon filled anti – static material. Impellers are factory set at an angle to provide maximum performance. Hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are dynamically balanced to ISO 14694 Grade G6.3.

Quality Management

Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All ATEX units are to be tested to ISO 5801:1997 (airside performance) and BS 848 Part 2: 1985 (sound performance).
Accessories
  • Ancillary PackAncillary Pack
  • AV MountsAV Mounts
  • Bell Mouth InletBell Mouth Inlet
  • Flexible ConnectionsFlexible Connections
  • Impeller Side GuardImpeller Side Guard
  • Matching FlangesMatching Flanges
  • Mounting FeetMounting Feet
  • SilencerSilencer